What are the main points to focus on in the daily maintenance of air compressors in air separation equipment?

What are the main points to focus on in the daily maintenance of air compressors in air separation equipment?
Nov 14, 2025
Author: DEAR AST

As the core power source of air separation equipment, the daily maintenance of the air compressor should focus on the following key points to ensure stable operation and energy efficiency optimization of the equipment:
1、 Lubrication system management
Regularly checking the oil level and quality is the foundation. Daily confirmation is required to ensure that the lubricating oil level is above the centerline of the scale; Sampling and testing of oil acid value, viscosity, and moisture every quarter. If the indicators exceed the standard (such as acid value>2mgKOH/g), they should be replaced immediately. At the same time, it is necessary to clean the oil filter monthly to prevent impurities from blocking the oil circuit.
2、 Cooling system maintenance
The cleaning of the cooler directly affects the heat dissipation efficiency. Use compressed air to blow back the fins of the cooler every week to remove accumulated dust; Disassemble the water-cooled cooler every six months. In addition, monitor the temperature difference between the inlet and outlet of the cooling water (normal range 5-8 ℃). If the temperature difference is too large, it may indicate water blockage or fan failure.
3、 Vibration and temperature monitoring
Dynamic monitoring is implemented through vibration sensors and infrared thermometers. Daily record the vibration value of the host bearing (≤ 7.1mm/s is qualified) and the temperature of the bearing shell (≤ 65 ℃). If the data fluctuates abnormally (such as a sudden increase of 30% in vibration value), the machine should be stopped immediately to check the rotor balance or coupling alignment. At the same time, it is necessary to regularly check the temperature of the motor winding (≤ 120 ℃) to prevent insulation aging from causing short circuits.
4、 Air intake filtration and sealing inspection
Clean the intake filter element weekly to ensure a pressure difference of ≤ 0.05MPa and avoid compressor surge caused by increased intake resistance. Check the leakage of the shaft seal every month (≤ 5mL/min).

DEAR Air Separation Solve YourWhat are the main points to focus on in the daily maintenance of air compressors in air separation equipment?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Regulation of liquid nitrogen throttle valveThe opening of the liquid nitrogen throttle valve not only affects the reflux ratio of the upper tower, but also affects the reflux ratio of the lower tower. When the opening is increased, the reflux ratio of the upper tower increases, while the reflux ratio of the lower tower decreases, the purity of the nitrogen in the upper tower increases, and the purity of the oxygen enriched night sky in the lower tower increases. However, after the opening is over, the purity of the liquid nitrogen decreases, and the reduction of the reflux ratio of the upper tower is also detrimental to the improvement of the purity of the liquid oxygen. Therefore, an equilibrium point should be found for the opening of the liquid nitrogen throttle valve. We can generally use the purity difference between liquid nitrogen and gas nitrogen to judge whether the opening is appropriate. Generally, the purity of the sprayed liquid nitrogen is equal to that of the upper towe
2026.11.11
In the field of air separation, entropy is the core thermodynamic parameter to measure the energy quality and irreversibility of the system, which directly determines the energy consumption level and operation efficiency of the unit. Entropy, with the symbol s, is essentially a measure of the degree of chaos and energy unavailability of a system, in kj/(kg ・ K). The second law of thermodynamics clearly states that the total entropy of an isolated system only increases but does not decrease, that is, the principle of entropy increase. The higher the entropy, the lower the energy quality, and the more difficult it is to convert into cold energy or useful work; The smaller the entropy, the more orderly the energy, and the more sufficient the available energy. The essence of air separation unit is the combination of cryogenic refrigeration and distillation separation, and the whole process is closely related to entropy. The ideal reversible process is an isentropic process, and the entropy
2026.11.10
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top