What are the requirements of the air separation equipment gas station for the surrounding air?

What are the requirements of the air separation equipment gas station for the surrounding air?
Dec 20, 2023
Author: DEAR AST

In order to ensure the safety of oxygen production, there are certain restrictions on the combustible impurities of hydrocarbons in the air at the suction port of the air compressor. According to GBl6912-1997 "Technical Safety Regulations for Oxygen and Related Gases", the impurity content should be lower than the allowable limit content specified in the table below.

The allowable limit content of hydrocarbons and other impurities in the air at the suction port

Names of impurities such as hydrocarbons

Permissible limit content (carbon content)/mg · m-3

There is a liquid air adsorption purification device inside the air separation tower

There is a molecular sieve adsorption purification device in front of the air separation tower

Acetylene

0.5

5

Acetylene derivatives

0.01

0.5

C5、C6saturated and unsaturated hydrocarbon impurities totaling

0.05

2

C3、C4saturated and unsaturated hydrocarbon impurities totaling

0.3

2

C2saturated and unsaturated hydrocarbon impurities total

10

10

Carbon sulfide(CS2)

Nitrogen oxide(NO)

Ozone(O3)

0.03

1.25

0.215

 

DEAR Air Separation Solve YourWhat are the requirements of the air separation equipment gas station for the surrounding air?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
What are the reasons why the oxygen production of air separation equipment cannot meet the target
2026.07.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top