Stroke of the piston compressor valve gate for small air separation unit

Stroke of the piston compressor valve gate for small air separation unit
Sep 01, 2026
Author: DEAR AST

The stroke of the valve plate of the piston compressor valve of the small air separation unit should be reasonably selected according to the speed and pressure of the compressor and should not be too large or too small. If the valve stroke is too large, the valve blade may not open fully and may also close with a hysteresis due to the inertia of the moving parts. At the same time, if the stroke is too large, it will increase the speed of the valve blade when opening and closing, and the impact on the restrictor and valve seat will increase. If the stroke of the valve blade is too small, it will increase the resistance loss, reduce the flow capacity and affect thesmall air separation unit productivity and efficiency of the compressor.

Dear Institute of Air Separation Design and Research has a number of patented technologies in the field of air separation energy saving. As an important user of industrial gases, oxygen, nitrogen and argon have become indispensable energy media in steel production, and the small air separation unit and large air separation unit are the "heart" of gas production.

山东临沂钢铁集团(三德)16000

 

DEAR Air Separation Solve YourStroke of the piston compressor valve gate for small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top