Installation of small air separation unit valves

Installation of small air separation unit valves
Dec 17, 2025
Author: DEAR AST

1 pay attention to the direction of the arrow on the valve and the process requirements of the media flow direction, in order to avoid installation small air separation unit valves errors.

2 The pipeline connected with the valve should be thoroughly cleared of dirt, dust and other foreign mechanical impurities before installation. Prevent damage of the sealing surface of the valve.

3 The cold valve on the cold box of small air separation unit should be installed at the same time as the corresponding bracket, and the valve stem should be tilted at 15℃.

4 pipeline and body welding to close the valve first and use cooling measures, the body temperature in welding is not higher than 200 ℃, so as not to deform the valve seals, affecting the normal use of the valve.

5 switch valve installation, the shaft should be in a horizontal position, flange bolts should be evenly cross-tightened.

6 remote control valve after installation. Should strictly check whether the command signal and the valve actuator action is synchronized, whether the full open and full close position is correct, and record the opening degree command and the actual opening degree relationship of the valve.

7 after the installation of the valve opening and closing should be flexible, after the connection of the pipeline and the cold test process are to check the valve opening and closing state, there shall be no jamming phenomenon to be considered qualified. Where the cold angle valve with sleeve, low temperature pneumatic film adjustment valve, in the cold test process, need to use special tools to tighten the flange bolts.

山东传洋集团18000

DEAR Air Separation Solve YourInstallation of small air separation unit valvesYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The main heat exchanger is the key equipment to ensure the performance of the air separation plant. Its functions in the air separation plant of the molecular sieve pre-filtration process are as follows: recover the cooling capacity of the reflux gas, ensure that the heat exchange temperature difference is within the design range; provide sufficient expansion gas in front of the expander to make up for the cooling loss of the air separation plant; provide raw air for the lower tower under the design conditions; and the working medium is in the main heat exchanger The resistance value in meets the process requirements.
2025.12.31
A low pressure nitrogen expander is added to the process design. The pressure nitrogen from the pressure tower and high pressure expander is expanded into low pressure nitrogen, which is combined with the nitrogen coming from the low pressure tower and fed into the charge gas compressor. This is specially set up for rapid oxygen load changes. The oxygen product flow rate during normal operation corresponds to the amount of oxygen contained in the amount of air entering the air separation unit. T...
2025.12.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top