当前位置: Home / Faq / Air separation FAQ /

How to deal with cavitation in DEAR Air separation unit liquid oxygen pumps?

How to deal with cavitation in DEAR Air separation unit liquid oxygen pumps?
Sep 17, 2021
Author: DEAR AST

DEAR Air separation unit.The overall heating procedure in cold state is shutdown - liquid discharge - standing - cold blowing - heating - system blowing. The end point of heating is until the outlet temperature of heating gas reaches normal temperature. The overall heating operation procedure in hot state is divided into two steps: heating and blowing. In order to completely remove the moisture and achieve the purpose of drying, the outlet temperature of heating gas should be higher than normal temperature. In order to remove solid impurities, the blowing out process is more important in the overall heating operation under hot state.Carbon dioxide precipitation stage. In this stage, only the switching heat exchanger is cryogenic to freeze the carbon dioxide in the heat exchanger, which is carried out by the low-pressure backflow gas until the cold end temperature reaches - 170 ℃; in the fourth stage, the purified low-temperature gas is used to further cool other equipment until liquid accumulates in the tower, and then the distillation condition is further adjusted.
DEAR Air separation unit.The heat capacity of the plate fin heat exchanger is small, and the start-up time of the air separation unit is short, at the level of 30-36 h; the start-up time of the air separation unit with the stone cold accumulator is 48-60 H. As far as operation is concerned, it is necessary to master the operation essentials: prevent moisture and carbon dioxide from entering the tower; strictly control the temperature difference between the cold end and the hot end; pay attention to the cooling of the main cooler; strictly control the temperature difference between the cold end and the hot end;The argon fraction is separated from oxygen and argon in a crude argon column. The argon fraction enters from the bottom and crude argon containing about 95% argon is obtained from the top. Because the boiling points of oxygen and argon are close to each other, it is difficult to separate them. About two thirds of argon is washed down.When the boiling point difference between rare gases and impurities is large, the method of segregation can be used to separate them. For example, nitrogen can be separated from neon and helium to obtain crude neon and helium.
DEAR Air separation unit.The refrigerating capacity provided by the refrigerator is usually precooled by the low-temperature working medium of the refrigerator in the air separation unit purified by molecular sieve, so as to improve the adsorption purification effect. This is the cooling capacity provided by the outside of the air separation unit, which refers to the heat carried away by the chilled water from the air. It can reduce the required throttling effect and the cooling capacity of the expander.DEAR Air separation unit.Check and confirm the opening and closing status of the equipment valves for interlock shutdown; check and confirm the alarm interlock items of the air separation unit. Recheck and confirm the interlock control that fails in case of power failure; start the air compressor and air precooling system according to the regulations; start the molecular sieve adsorber according to the regulations.DEAR Air separation unit.When measuring the pressure of piston compressor and similar equipment, shock absorber must be added in the pipeline to prevent the damage of pressure gauge components. Shock absorber usually uses buffer vessel with orifice, or directly uses needle valve instead of globe valve.

DEAR Air Separation Solve YourHow to deal with cavitation in DEAR Air separation unit liquid oxygen pumps?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What are the requirements for selecting materials for high purity nitrogen gas distribution pipelines in small air separation unit?   High purity nitrogen gas has to be transported through pipelines to the point of use of the small air separation unit. In order to meet the quality requirements of the gas for the process, the selection of materials for the piping system and the quality of construction need to be paid more attention to during the construction process, provided that the gas ...
2026.07.09
Liquid air separation plant solutions Most liquid air separation plant cold energy receiving stations have a peaking role, their use is generally for domestic gas or car refuelling, with high and intermittent periods of gas consumption, for example 1-2 hour peaks in the morning and midnight. If the liquid air separation plant vapourisation plant is intermittent, the plant will not operate continuously. The solution is based on the intermittent use of liquid air separation plant and is character...
2026.07.08
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top