Why does the liquid oxygen surface of the DEAR Biogas purification unit plate fin condensing evaporator have to be fully immersed in the plate unit?

Why does the liquid oxygen surface of the DEAR Biogas purification unit plate fin condensing evaporator have to be fully immersed in the plate unit?
Aug 30, 2021
Author: DEAR AST

For the first type, it is usually adjusted by changing the liquid level of evaporation side, that is, changing the size of heat transfer area. This regulation condition is relatively stable, and the pressure change of upper and lower tower is small. For the second type, when the liquid oxygen in the tube reaches 30% of the apparent liquid level, the churning condition can be established, and the heat transfer surface can fully play the role of heat transfer. Therefore, it can not be adjusted by changing the liquid level on the evaporation side.After cold blowing, the temperature decreases and a flat head peak appears. The longer the curve distance of the flat head peak is, the more water enters into the molecular sieve. In order to prevent the water inflow accident of Molecular Sieve Purifier, attention should be paid to the operation: the air cooling tower should be operated according to the operating procedures, first the gas is injected, and then the water is injected after the pressure rises and stabilizes; the gas volume should not be increased or reduced suddenly;
The extracted saturated liquid nitrogen is also at this temperature. The temperature of the liquid nitrogen is about 16 ℃ higher than that of the gas nitrogen in the upper tower. Therefore, when the two fluids flow through the liquid nitrogen subcooler, through heat exchange, the liquid nitrogen releases heat and is cooled into supercooled liquid, and the gas nitrogen becomes superheated steam due to heat absorption.DEAR Biogas purification unit.For equipment with acetylene adsorber, special attention should be paid to not too much gas flow through acetylene adsorber when blowing medium pressure. Therefore, when pulling out the stem of section-2 valve, the stem of section-3 and section-4 valve must be pulled out first, and the stem of section-2 valve cannot be pulled out alone for blowing.DEAR Biogas purification unit.Swirl plate. It consists of several swirling trays with metal structure. This kind of structure has little resistance and will not be damaged. It has been used as an improved one for quite a long time. But the heat transfer effect is not as good as packed tower. Sieve tray tower. The drenching tray with larger diameter and spacing is adopted. Both nitrogen and water pass through the screen. Because the water cooling tower does not work continuously and stably, the cooling effect is not ideal, so it is no longer used.
Before filling molecular sieve, check the sieve bed to avoid molecular sieve leakage, otherwise it should be treated. There should be no oil and other sundries in the tank; the filling personnel should not wear work shoes with nails to avoid stepping on the sieve bed; they should wear clean work clothes without oil. Several standard height marks should be made in the middle part. First check the ring chamber, fill the aluminum glue to reach the standard height, and then fill the molecular sieve.DEAR Biogas purification unit.Due to the impact of air flow, the actual content of carbon dioxide in the air at the cold end of the accumulator and the switching heat exchanger will exceed the saturation content, which will also affect the operation cycle. In particular, the cold section of the switching heat exchanger is too short, and the carbon dioxide precipitation zone is shortened, which makes it easier to bring part of carbon dioxide into the column, resulting in the increase of resistance of the distillation column, the weakening of main cooling heat transfer, the blockage of the subcooler, the increase of the down tower pressure, and the decrease of the air intake and oxygen output.
DEAR Biogas purification unit.Reduce the temperature after expansion. The lower the temperature after expansion, the greater the temperature difference with the positive air, and the stronger the heat transfer. Therefore, at this stage, the temperature after the expander should be controlled as low as possible without liquefaction, such as - 180 ~ + 185 ℃.DEAR Biogas purification unit.When installing the fractionator, attention must be paid to the two "vertical correction irons" on the outer side of the shell, and the verticality shall not be greater than 1 / 1000. If the fractionator is not installed vertically, it means that the tray is not horizontal. In this way, in the operation of the fractionator, the thickness of the liquid layer on the tray will be uneven, some places are thicker, some places are thinner, and some places even have no liquid.The reflux liquid needed for distillation is the liquid partially condensed in the condenser from the rising gas. The cold source is throttled liquid nitrogen, part of which comes from the main tower and part from the liquid nitrogen condensed in the bottom evaporator. The refined argon product can be extracted in liquid form, or it can be pressurized to recover the cold capacity and then filled into the bottle.

DEAR Air Separation Solve YourWhy does the liquid oxygen surface of the DEAR Biogas purification unit plate fin condensing evaporator have to be fully immersed in the plate unit?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Internal compression air separation process is a process form in which liquid products are pressurized by liquid pump in the cold box, and then sent out of the cold box after reheating by high-pressure heat exchanger. The working pressure of internal compression process generally exceeds the critical point of oxygen and nitrogen. Heat transfer of liquid in supercritical state is a major feature of internal compression process. In the distillation process, due to the difference of product types and acquisition methods, there is a big difference between the material import and export of internal equipment and external compression process. In the internal compressed air separation process, the pressure of oxygen is not limited, the maximum output of nitrogen can reach 2.8 times of that of oxygen, and the extraction rate of argon can reach about 85%. The internal compression air separation process is generally composed of internal compression system, air precooling system, molecular sie
2024.04.18
Leakage is the easiest failure of regulating valve during operation. Some leak at the welding place, and some leak at the sealing place of the stuffing. When leakage occurs at the welding site, repair welding can be done during overhaul; when leakage occurs at the sealing site of the stuffing, new stuffing can be replaced. Sometimes the film of the film actuator is damaged, and the valve stem can't act normally with the air pressure signal, so it needs to be replaced with a new film. In order to avoid the deformation of the valve stem affecting the regulating function, it is better to stand on the pipeline when installing the regulating valve. It is not suitable to install the low-temperature film regulating valve horizontally, and it should form an angle above 150 with the level so that the sealing place of the stuffing is not affected by the liquid. The slanting valve must be lifted. When operating, always pay attention to whether the regulating valve gets stuck. The sealing fille...
2024.04.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top