What are the basic terms of air separation unit (2)

What are the basic terms of air separation unit (2)
Aug 16, 2021
Author: DEAR AST

8 nitrogen

 

Molecular formula N2, molecular weight 28.0134 (according to 1979 international atomic weight), colorless, odorless, inert gas. The density is 1.251kg/m3, the melting point is 63.29k, and the boiling point is 77.35k at 101.325kpa. It is a kind of asphyxiating gas because it is not active and can't burn.

 

9 gaseous nitrogen for industrial use  

 

The nitrogen content of industrial gaseous nitrogen produced by air separation equipment is more than or equal to 98.5% (volume ratio).

 

10 pure nitrogen

 

The nitrogen content of nitrogen produced by air separation equipment is more than or equal to 99.995% (volume ratio).

 

11 high purity nitrogen

 

The nitrogen content (volume ratio) of nitrogen produced by air separation equipment is greater than or equal to 99.9995%.

 

12 liquid nitrogen (liquid nitrogen)

 

Nitrogen in liquid state is transparent and easy to flow. At 101.325kpa, the boiling point is 77.35k and the density is 810kg / m3. Liquid nitrogen can be produced by low temperature air separation equipment or liquefied by gaseous nitrogen.

 

13 liquid air (liquid air)  

 

The air in liquid state is light blue and easy to flow. At 101.325kpa, the boiling point is 78.8k and the density is 873kg / m3. Liquid air is the intermediate product in the process of air separation.

 

14 oxygen enriched liquid air

 

It refers to liquid air with oxygen content more than 20.95% (volume ratio).

 

15 fraction liquid nitrogen (waste liquid nitrogen)  

 

The liquid with nitrogen content of 95% ~ 96% (volume ratio) is extracted from the proper position of the lower tower.

 

16 sewage nitrogen

 

The nitrogen content is 95% ~ 96% (volume ratio) in the upper part of the upper tower.

 

17 standard state   

 

It refers to the gas state when the temperature is 0 ℃ and the pressure is 101.325kpa.

 

18 air separation

 

The process of separating its components from air to produce oxygen and nitrogen and to extract argon, neon, helium, krypton, xenon and other gases.

DEAR Air Separation Solve YourWhat are the basic terms of air separation unit (2)You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top