What safety problems should be paid attention to in the hydrostatic test of oxygen cylinders for DEAR Cryogenic air separation unit?

What safety problems should be paid attention to in the hydrostatic test of oxygen cylinders for DEAR Cryogenic air separation unit?
Jul 26, 2021
Author: DEAR AST

The quality of the liquefier can be judged by the difference between the temperature after the expander and the temperature of the waste nitrogen out of the liquefier. If the temperature rise is large, it means that the working condition is good; if the temperature rise is not obvious, the liquefier may be blocked and not play a role in liquefaction.DEAR Cryogenic air separation unit.Its temperature can be lower than that of the cooled medium (chilled water, etc.), so it can absorb heat Q2 from the cooled medium in evaporator 4, and the refrigerant will evaporate into low-pressure steam and return to the compressor for circulation. Therefore, compared with the refrigeration in the oxygen generator, the common point of the refrigeration in the refrigerator is that the compressor needs to consume work.DEAR Cryogenic air separation unit.The purpose of throttling is to obtain low temperature, so the greater the effect of throttling temperature drop, the better. Pressure difference before and after throttling. The greater the pressure difference before and after throttling, the greater the temperature drop. To increase the pressure before throttling, we must increase the discharge pressure of the compressor, and correspondingly increase the energy consumption of the compressor, which is not what we want.
DEAR Cryogenic air separation unit.If the heat exchange effect of the air compressor end cooler (or nitrogen water precooler) is not good, or the cooling water temperature is high, the air temperature into the device will rise. If the air volume remains unchanged, the cooling capacity required to cool the air to near the liquefaction temperature will increase accordingly.DEAR Cryogenic air separation unit.When the temperature of the air entering the unit increases, not only the heat load of the accumulator (or switching heat exchanger) increases, but also the amount of water brought in increases, which increases the burden of self cleaning. With the increase of water freezing, the heat transfer efficiency is reduced. When the heat transfer area of the heat exchanger is fixed, the increase of the heat load and the poor heat transfer effect will inevitably lead to the increase of the temperature difference between the cold end and the hot end.DEAR Cryogenic air separation unit.The key to affect the total cooling capacity is the maintenance, installation quality and operation level of the expander. In the start-up stage, to prevent the moisture and carbon dioxide from freezing in the expander, to prevent the expander filter from being blocked, and to extend the operation time of the expander at a higher inlet temperature as far as possible are all measures to increase the total cooling capacity and shorten the start-up stage.
DEAR Cryogenic air separation unit.Damp insulation material will greatly reduce the thermal insulation performance and increase the loss of cooling. If the cold insulation box is not sealed tightly, after the internal temperature of the cold insulation box decreases, the external wet air will invade, and the internal condensation or even freezing may occur. Therefore, it is necessary to ensure the sealing of the cold box, and fill a small amount of dry gas to maintain micro positive pressure.DEAR Cryogenic air separation unit.The structure of water cooling tower for large air separation plant in China is as follows: packed tower. In the early stage, it was equipped with ceramic lacigo ring, which had good heat transfer effect and little resistance. However, when it is used in the self cleaning low-pressure process, because the switching system is switched every few minutes, the air flow has a great impact on the porcelain ring during the switching venting, which is easy to cause the porcelain ring damage and increase the resistance. There are also plastic rings to increase strength.

DEAR Air Separation Solve YourWhat safety problems should be paid attention to in the hydrostatic test of oxygen cylinders for DEAR Cryogenic air separation unit?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top