What should I do if the DEAR Biogas purification unit liquid oxygen level gauge tube is clogged?

What should I do if the DEAR Biogas purification unit liquid oxygen level gauge tube is clogged?
Jul 21, 2021
Author: DEAR AST

Expander, freezer, air precooling system and argon purification system shall be shut down by interlocking. If there is no shutdown, it should be stopped manually; stop the delivery of oxygen, nitrogen and other products, stop the removal of liquid oxygen, liquid nitrogen and liquid argon; close the water valve connecting the air precooling system with the outside. The rest are operated according to the requirements of normal shutdown. After the above operation, find out the cause of the fault and prepare for restart.In practical operation, the temperature balance between two groups is mainly adjusted according to the temperature difference in the middle of two groups of cold accumulators or two groups of switching heat exchangers. The middle temperature difference between groups is generally controlled within 10 ℃. In addition, the actual control in the operation is often the temperature of the air at the outlet of the circulation or the middle outlet, no matter whether it is the actual middle temperature or not.
DEAR Biogas purification unit.When the air quantity decreases, the rising steam quantity and reflux liquid quantity in the tower decrease, but the reflux ratio remains unchanged. Under normal conditions, it has little effect on the purity of oxygen and nitrogen products. According to the material balance, the output of oxygen and nitrogen will decrease when the air volume is reduced.DEAR Biogas purification unit.The operation condition of refined argon tower mainly depends on whether the condenser and evaporator work well together. If the cooling capacity of the condenser is too much, the condensation capacity is too large, and the reflux liquid is too much, the nitrogen part will not evaporate sufficiently, and the argon at the bottom may be polluted by nitrogen, thus reducing the purity of argon.DEAR Biogas purification unit.The central air extraction port of each accumulator in the central air extraction process of the accumulator enters the automatic valve box of the central air extraction through the central air extraction valve. When one of the cool accumulators in each pair flows with positive air, part of the air is extracted from the middle part, and then converges to the CO2 adsorber through the regulating-7 valve.
When parking, it is not easy to produce convection when it is cold at the bottom and hot at the top. The cold gas in the tower goes through low temperature first and then high temperature, so the cold loss is less. Its disadvantage is that the hot pipe is on the top, which is not convenient for pressure test. In addition, when the air cooling tower fails and the water enters the molecular sieve system, and then enters the plate fin heat exchanger, the water will enter the low temperature zone, so it is troublesome to heat and thaw.DEAR Biogas purification unit.The lower the pressure behind the expander, the greater the pressure drop in the expander and the greater the unit cooling capacity. However, due to the expansion of the gas into the distillation column, there is little room for pressure change. The higher the adiabatic efficiency of the expander, the greater the refrigerating capacity.In order to ensure self cleaning of all low pressure air separation unit, the temperature difference at the cold end of switching heat exchanger must be controlled within the allowable temperature range to ensure self cleaning. The self clearing temperature difference at the cold end is the difference between the temperature when the positive air passes through the cold end section and the temperature when the backflow gas passes through the section. In normal operation, the measured temperature difference at the cold end is the self clearing temperature difference.

DEAR Air Separation Solve YourWhat should I do if the DEAR Biogas purification unit liquid oxygen level gauge tube is clogged?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top