How can DEAR Air separation equipment properly blow out oil and water separators?

How can DEAR Air separation equipment properly blow out oil and water separators?
Jul 06, 2021
Author: DEAR AST

Plate fin type is widely used in various air separation plants, mainly used in medium and large air separation plants. It is the condensation and evaporation of gaseous nitrogen and liquid oxygen in the adjacent channels. The adjustment of their heat load should be carried out according to their different working principles.The middle pumping volume should be small at the beginning. For the 6000m3 / h oxygen generator, 200m3 / h can be pumped first. With the continuous decrease of the temperature of the intermediate extraction, the gas extraction volume is gradually increased. Increase 500m3 / h each time, so that the temperature at the bottom of the accumulator does not rise sharply and the outlet temperature of the expander is not lower than - 180 ℃.DEAR Air separation equipment.When the temperature is constant, the partial pressure of water vapor in saturated air (that is, the saturated pressure of water vapor at that temperature) is a constant value, which has nothing to do with the total pressure of saturated air. In other words, regardless of the total pressure of saturated air, the mass content of water vapor in the same volume of saturated air is the same. Therefore, the higher the total pressure of the same mass of saturated air is controlled, the smaller the total volume and the less water (mass) contained in the saturated air.
When the pressure of the upper and lower towers is constant, the temperature difference between the main cooling tower and the main cooling tower will be reduced by increasing the purity of liquid oxygen, and the temperature difference between the main cooling tower and the main cooling tower will be reduced by increasing the purity of gas nitrogen. If the purity and pressure of gas nitrogen remain unchanged and the purity of liquid oxygen is constant, the temperature difference of condensing evaporator can be reduced by increasing the pressure of upper tower.DEAR Air separation equipment.According to the law of conservation of energy, the total energy (enthalpy) of the fluid before and after throttling should remain unchanged. However, each part of the three components of enthalpy: kinetic energy of molecular motion, potential energy of molecular interaction and flow energy may change.DEAR Air separation equipment.When the expander expands, the decrease of gas temperature is not only caused by the decrease of pressure, resulting in the increase of molecular potential energy, but also the decrease of molecular kinetic energy. It is mainly caused by external work, so the effect of temperature drop is much greater than that of throttling.
DEAR Air separation equipment.It is known from practice that as long as there is a temperature difference, the heat will be transferred spontaneously. Moreover, heat is always transferred from the fluid with higher temperature to the fluid with lower temperature. Temperature difference is the power of heat transfer. The heat transfer processes of three kinds of heat exchangers are different, but their basic rules are the same.DEAR Air separation equipment.Low temperature liquid evaporator has atmospheric type and steam water bath type. The atmospheric evaporator is composed of finned evaporation tubes, which are placed in parallel in several groups and have a large volume. With the flow of low temperature liquid, the surface of evaporation fin will be frosted gradually. The frost should cover the evaporator surface.The fundamental purpose of setting nitrogen water precooler is to reduce the temperature of air entering the air separation column and avoid the temperature fluctuation. Because the inlet air temperature directly affects the working conditions of the switching heat exchanger and the distillation column, as well as the economy of the whole air separation unit.

DEAR Air Separation Solve YourHow can DEAR Air separation equipment properly blow out oil and water separators?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Air compressor intermediate cooler is generally shell-tube structure. Water is supplied inside the pipe, and gas is supplied between the pipes, which plays a cooling role through the heat exchange of fluid inside and outside the pipe. The reasons that affect the cooling effect of compressor intermediate cooler include: 1) insufficient cooling water. The heat of the air is not enough to be taken away by the cooling water, resulting in the increase of the next level of suction temperature, the decrease of gas density, and finally the reduction of exhaust volume. Therefore, the water supply pressure of cooling water should be closely monitored during operation to control the water supply. The process generally requires that the cooling water pressure should be greater than 0.15MPa (surface pressure); 2) the cooling water temperature is too high. High water temperature reduces the temperature difference between water and gas, and reduces the effect of heat and cooling. Even if the amoun...
2025.01.09
What requirements and regulations should be met for the assembly of meter tube, cold insulation box and strength and air tightness test before positioning of air separation equipment
2025.01.08
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top