How is the inlet pressure of the DEAR Air separation plant oxygen press automatically regulated?

How is the inlet pressure of the DEAR Air separation plant oxygen press automatically regulated?
Jul 01, 2021
Author: DEAR AST

First of all, the steam pressure and flow rate required for the molecular sieve heating should meet the requirements of process design. Heating regeneration process can be judged by regeneration temperature curve. Pressure relief stage: due to the decrease of pressure, the adsorption capacity of molecular sieve decreases, and the water and carbon dioxide molecules that were originally adsorbed are partially desorbed, resulting in the decrease of temperature.DEAR Air separation plant.The temperature difference between nitrogen and air is increased from 4 ℃ to 6.5 ℃ and the temperature difference between oxygen and air is increased from 5 ℃ to 18.5 ℃ because the temperature of air entering the device is increased from 30U to 51.5 ℃. At this time, we should check the cause of air temperature rise into the tower and eliminate it.In terms of manufacturing process, limited by the size of salt bath furnace, the maximum length of plate unit can only be 2.1m, and the section size is 750mm × 700mm ~ 1100mm × 1000mm. At present, with the development of technology, the longest plate unit can be 6m long.
According to the maximum cooling capacity and the cooling capacity required for cooling and liquid accumulation, the start-up time of the unit also needs to be more than 36 hours. Large air separation units are generally equipped with liquid oxygen storage tanks as emergency standby oxygen. If necessary, it is theoretically possible to fill the tower with liquid oxygen to shorten the start-up time of the air separation unit.DEAR Air separation plant.The temperature difference between the air inlet and the reflux outlet of the fractionator is measured by thermometers. The difference between the inlet air temperature and the outlet reflux air temperature is called "hot end temperature difference", which is one of the important bases for operation. Glass thermometer is often used to measure the temperature of small air separation unit. If the thermometer is not installed correctly and the indication value is not accurate, it may cause misoperation.DEAR Air separation plant.The liquid level should be stable. The stability of liquid oxygen level indicates the balance of cooling capacity of the equipment. If the liquid oxygen level changes from high to low, it is very difficult to adjust the purity. The expansion volume and the opening of liquid air and liquid oxygen control valves should be adjusted reasonably to make the liquid oxygen surface stable.
In general, it will not exceed the allowed air volume of the upper tower, so it is not necessary to pump dirty liquid nitrogen to directly increase the reflux ratio of the distillation section. The extraction port, pipeline and valve are reduced, and the process is simplified. Generally, the lower tower of oxygen generator with large output of pure gas nitrogen product does not pump liquid nitrogen.When the pressure exceeds the specified value, the valve will open automatically, and the valve will close automatically when the pressure is restored by removing part of the gas. Before installation, the safety valve should be debugged according to the usage before installation. The safety valve is generally calibrated at least once a year. The safety valve should be adjusted on the system, and should not leak under the working pressure, and then be lead sealed.Due to the large amount of molecular sieve, the molecular sieves produced by different kilns are different. Therefore, the molecular sieves from the same batch of kilns should be evenly filled into two molecular sieve tanks. After the completion of filling, use the flattening mechanism to flatten, and check whether the molecular sieve filling reaches the standard height (the ring chamber has been buried under the molecular sieve). The molecular sieve is leveled again until the molecular sieve on the sieve bed is smooth and there is no concave convex problem. If there is no problem, it can be considered that the filling work is finished.

DEAR Air Separation Solve YourHow is the inlet pressure of the DEAR Air separation plant oxygen press automatically regulated?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top