What should air separation plant pay attention to when using degreaser?

What should air separation plant pay attention to when using degreaser?
Jun 21, 2021
Author: DEAR AST

The temperature difference between nitrogen and air is increased from 4 ℃ to 6.5 ℃ and the temperature difference between oxygen and air is increased from 5 ℃ to 18.5 ℃ because the temperature of air entering the device is increased from 30U to 51.5 ℃. At this time, we should check the cause of air temperature rise into the tower and eliminate it.Air separation plant.According to the weight of different fractionating tower, select appropriate steel wire rope, hang the tower flat on the sleeper, and carry out air tightness test; tie the steel wire rope to the lower part of the upper shell, and pad it with about 10 mm wood around to prevent the shell from deformation, and then lift it to the specified position with crane;The newly installed fractionator must be thoroughly heated and purged before start-up and long-term shutdown. After putting into operation, when the suspension fault of the fractionator cannot be eliminated, or the pressure difference before and after the heat exchanger pressure is greater than 0.5MPa at the end of the operation cycle, or the purity and yield of oxygen and nitrogen are decreased, heating and blowing should be carried out.
If the effective energy of the environmental state is zero, the air is separated into oxygen and nitrogen, that is, in an unbalanced state with the environment, it needs to consume energy, that is, the separated product has effective energy. Because the raw air is in the environmental state, its effective energy is zero.Air separation plant.When water enters the cold accumulator (or switching heat exchanger) to freeze and block the channel, the resistance will be greatly increased, the upper tower pressure and the exhaust pressure of the air compressor will be increased, the switching sound will become dull and elongated, and a large amount of water gas can be seen in the waste nitrogen discharge pipe. These phenomena can be used to judge the water inflow accident of the cold accumulator (or switching heat exchanger).At the beginning of heating, it is necessary to turn down the oxygen and nitrogen vent valves, limit the discharge volume, increase the low pressure pressure, increase the gas volume of the pipeline with large resistance, and speed up the heating thoroughly. When the fractionator is heated, the molecular sieve purifier also needs to be heated. If the low pressure is too low, the regeneration of purifier will be affected. But the pressure should not exceed the normal working pressure to ensure safety.
Krypton and xenon are mainly used in electric light sources. The lamp filled with krypton, xenon and argon mixture has the advantages of small volume, long service life and high efficiency. Generally, the efficiency is 4-5 times higher than that of incandescent lamp, and the service life can be increased by 2-3 times. Krypton and xenon are used in flash lamp and stroboscope. Because the discharge intensity of xenon lamp is higher than that of sunlight, the long arc argon lamp filled with xenon gas, commonly known as "little sun", has strong fog piercing ability, and can be used for lighting in airports, stations, docks and other places, as well as in the battlefield.Air separation plant.The amount of rising steam at the liquid layer thickness is less. Although the oxygen in the gas is fully condensed, due to the less amount, the latent heat of condensation is also less, so the amount of nitrogen evaporation in the liquid is less, which also affects the distillation. Due to the reduction of distillation efficiency, the purity of oxygen and nitrogen will be affected. The degree of influence varies according to the inclination of the tray.

DEAR Air Separation Solve YourWhat should air separation plant pay attention to when using degreaser?You can also learn about otherAir separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why is the cryogenic air separation air compression system the most power consuming link?
2026.03.23
Screw compressor is a positive displacement compressor from the mechanical type, which is composed of the driving rotor and driven rotor, the main body and a pair of synchronous gears. Therefore, the common faults of screw compressor are as follows: 1. The bearing is burnt out. Because of the foreign matter in the oil system, the oil pressure and the quality of the oil are reduced, resulting in the bearing burning out. The main treatment methods are: check the oil supply system; clean the oil filter and the cooling pipe of the oil cooler; check and adjust the oil pressure regulating valve; test the oil quality, and replace the oil when it is not good; check and deal with the oil leakage points. 2. The rotor is burnt out. When foreign matters enter into the compressed medium system, the temperature of the rotor rises, the temperature of the cooling oil of the rotor increases due to the high temperature of the inhaled medium, and the compression ratio increases, which may cause the
2026.03.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top