Home / All Air Separation tags /

Small air separation unit heat exchanger chip resistance

Small air separation unit heat exchanger chip resistance
Heat exchanger core resistance to logistics resistance on the uneven distribution of logistics has a greater impact, when the core resistance is smaller airflow distribution distribution plant is not uniform. This is the way to solve the problem of uneven airflow distribution by improving the structure of the head.
Cases of Small air separation unit heat exchanger chip resistance
More
News of Small air separation unit heat exchanger chip resistance
More
May 06, 2021
On April 16, it was reported that DEAR air separation Co., Ltd. solemnly held the “Turnkey ceremony” of the Kaifeng Air Separation Staff University. H
Dec 23, 2020
According to the news on December 21, DEAR air separation launched a “Welcome the Winter Solstice and dumpling making together” activity to celebrate
Solutions of Small air separation unit heat exchanger chip resistance
More
Type 8000/2000-240 solution for small and medium-sized air separation plant in circular economy industry
Circular economy is also characterized by resource conservation and recycling, which is a harmonious economic development mode with the environment. All materials and energy can be used reasonably and persistently in this continuous economic cycle, in order to reduce the impact of economic activities on the natural environment as small as possible. As an emerging industry, the market development in the future is inestimable.
2400/1000-type solution for small and medium-sized air separation plant in nonferrous industry
Formulate construction guidelines for non-ferrous metal intelligent mines and factories, and guide the construction of industry intelligent standardization. Reducing production energy efficiency and overall controllable cost, promoting the rapid iteration of production equipment and improving enterprise profits are the problems that need to be solved urgently in current industry. Recently, DEAR air separation cooperated with customers and signed a 2400/1000-type small and medium-sized air separation plant project, which was highly recognized by customers through reasonable scheme design.
Faq of Small air separation unit heat exchanger chip resistance
More
How is the relation between expander and refrigerating capacity of air separation equipment?
Dec 15, 2025
When the exhaust temperature of the piston compressor is higher than the design value, the most direct impact is that the lubricating oil is carbonized, which leads to the compressor parts burned out because of not getting good lubrication. If the temperature of the compressor is too high during actual operation, the cause should be analyzed in time and corresponding preventive measures should be taken. The following methods can be used for reference in practice. 1. Reducing the inlet air temperature can directly reduce the exhaust temperature. Check the intercooler to ensure the cooling effect of the intercooler. 2. The installation of the valve and the selection of the spring should be standardized to ensure the normal operation of the valve and minimize the loss of inlet and outlet pressure. 3. Strengthen the cooling of cylinder to ensure the normal compression process index. 4. Internal leakage is the main reason for the increase of exhaust temperature. 5.For multist
Dec 11, 2025
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top