Answer: when the main cooling is seriously leaked, nitrogen with higher pressure will leak into the low pressure oxygen side in large quantities, then...
Answer: only when the quantity and state of materials entering and exiting the distillation tower and each stock of materials completely accord with t...
The most likely leakage of switching heat exchanger is the welding line, especially the joint of the head and the pipeline. Most of the causes of leak...
One-week project progress --- Minyuan 15000 project● Minyuan KDON (Ar)-15000/15000-500 type complete set of air separation engineering project support...
The technical requirements of crude argon tower include:1. the manufacture, inspection and acceptance of crude argon tower should comply with the prov...
The pressure value measured by the pressure gauge reflects the pressure level, but it is not the actual pressure. According to the working principle o...
I, a member of the DEAR family, have been in this big family for 9 years and worked as a driver in this family. For many years, I have been grateful t...
On the morning of February 19, 2012, four leaders of the city, including municipal party secretary Qi Jinli, Mayor Ji Bingwei, director of the Stan...
After the air of the raw material entering the lower tower is rectified, the nitrogen with higher purity is obtained on the top. Nitrogen enters the m...
Not long ago, a client from Henan made a public bidding for a 3800-hour air separation set. At that time, the office building of this unit was very bu...
Distributed Control System (DCS): Our company has been devoting to the development and application of control system in air separation plant for many ...