Home / All Air Separation tags /

Anti-static grounding of small air separation units

Anti-static grounding of small air separation units
Classical grounding should be considered in the equipment control room where pcs, plc, sis and other systems are installed. Anti-static grounding should be performed on the conductive ground, raised floor, workbench, etc. in these control rooms.
News of Anti-static grounding of small air separation units
More
Oct 17, 2025
The 40,000-grade Air Separation equipment, designed, manufactured, equipped, installed, and commissioned by DEAR Air Separation, achieved a successful
Aug 27, 2025
DEAR Air Separation Holds Science and Innovation Fund Award Ceremony Innovation Achievement: DEAR Instrumentation Smart Electrical Box Assembly Line
Solutions of Anti-static grounding of small air separation units
More
Small air separation plant KDON(Ar)-8000/16000-220 solution for metallurgical industry
DEAR air separation has provided a number of complete solutions for the metallurgical industry for many years, accumulated rich experience, and helped the efficient development of the metallurgical industry. With many years of service experience in the metallurgical industry, DEAR air separation provides customer with the small air separation plant KDON (Ar) - 8000 / 16000 / 220, which is mature technological, operating reliable, operating convenient, and energy saving intelligent, that is highly recognized by customers.
Large complete air separation plant KDON(Ar)- 36000/70000-1200 solution for chemical industry
DEAR air separation has provided many sets of air separation plant for chemical industry for many years, with rich experience and the safe and stable unit operation. This unit adopts molecular sieve purification, booster turbine expander to supply the cooling capacity of the unit, and the whole rectification hydrogen-free argon production process. The rapid growth of enterprises in the industry is accompanied by the demand for production and the demand for air separation plant. DEAR air separation has cooperated with customers in the large-scale complete set of air separation plant KDON (AR) - 36000/70000-1200 project, which has meet the capacity demand and safety demand of the enterprise.
Faq of Anti-static grounding of small air separation units
More
The amount of liquid nitrogen removed from the lower column of the air separation unit will affect the purity of the liquid nitrogen in the lower column and the oxygen enriched liquid air at the bottom of the column. When the liquid nitrogen removal amount of the lower column increases, the reflux liquid participating in the heat and mass exchange of the lower column will be reduced, the temperature rise of the rising steam on the column plate will be correspondingly reduced, the condensation of the rising steam will not be sufficient, the oxygen component will be condensed less, the purity of nitrogen at the column top will be reduced, and the purity of liquid nitrogen will be naturally reduced. At the same time, the temperature rise of the downflow liquid will increase, the liquid evaporation will be more sufficient, more nitrogen components will be evaporated to the top of the column, and the purity of the liquid air at the bottom of the column will be improved accordingly.
Jan 23, 2026
What is the function of air separation equipment air cooling tower water-proof pressure interlocking?
Jan 19, 2026
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top