Anti-static grounding of small air separation units

Anti-static grounding of small air separation units
Classical grounding should be considered in the equipment control room where pcs, plc, sis and other systems are installed. Anti-static grounding should be performed on the conductive ground, raised floor, workbench, etc. in these control rooms.
News of Anti-static grounding of small air separation units
More
Aug 19, 2021
On August 6th, Kaifeng Dear Air Separation Industry Co., Ltd. cooperated with Qinghai Asia Silicon Semiconductor Co., Ltd. for the third time and sign
Jul 30, 2021
Torrential rainfall hit Henan a few days ago and has inflicted heavy casualties and property losses. In the rainfall, Zhengzhou and Xinxiang were suff
Solutions of Anti-static grounding of small air separation units
More
Small air separation plant KDON(Ar)-8000/16000-220 solution for metallurgical industry
DEAR air separation has provided a number of complete solutions for the metallurgical industry for many years, accumulated rich experience, and helped the efficient development of the metallurgical industry. With many years of service experience in the metallurgical industry, DEAR air separation provides customer with the small air separation plant KDON (Ar) - 8000 / 16000 / 220, which is mature technological, operating reliable, operating convenient, and energy saving intelligent, that is highly recognized by customers.
Large complete air separation plant KDON(Ar)- 36000/70000-1200 solution for chemical industry
DEAR air separation has provided many sets of air separation plant for chemical industry for many years, with rich experience and the safe and stable unit operation. This unit adopts molecular sieve purification, booster turbine expander to supply the cooling capacity of the unit, and the whole rectification hydrogen-free argon production process. The rapid growth of enterprises in the industry is accompanied by the demand for production and the demand for air separation plant. DEAR air separation has cooperated with customers in the large-scale complete set of air separation plant KDON (AR) - 36000/70000-1200 project, which has meet the capacity demand and safety demand of the enterprise.
Faq of Anti-static grounding of small air separation units
More
When the general motor in the air separation plant is started, the current that the stator of the motor takes from the power grid is about 5 ~ of the rated current of the motor ~ 7 times. After starting the small motor for one or two seconds, the current decreases rapidly as the rotating speed of the rotor gradually rises; while the large motor needs more than ten seconds, even dozens of seconds before the rotor reaches the stable rotating speed. That is, until the start-up ends, the current drops to the rated value. If the starting current of asynchronous motor is high, what problems will it bring to the use? If this motor starts frequently when it is used, the motor will heat severely due to the influence of starting current, which will affect the normal service life of the motor. In addition, if the starting times of the motor used are not frequent, when its capacity exceeds 30% of the power transformer capacity, due to the large starting current, it will cause the overvoltage dr...
Nov 28, 2024
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
Nov 21, 2024