Home / All Air Separation tags /

Air separation equipment customization

Air separation equipment customization
The air separation plant customization should consider the requirements of the enterprise for output and purity, and pay attention to many indicators, such as unit energy consumption, extraction rate, start-up time, operation cycle, heating and thawing time, safety, stability, etc. In addition, air separation equipment customization also needs to consider the enterprise budget, plant environment and other factors.
News of Air separation equipment customization
More
Sep 30, 2020
On September 24, a delegation from QinZhou Federation of Industry and Commerce of Guangxi province came to DEAR air separation for investigation and i
Jul 31, 2020
On July 29, it was reported that Kaifeng DEAR air separation project department organized the kick-off meeting of KDON(Ar)-16000 / 1600 / 550 air sepa
Solutions of Air separation equipment customization
More
Large air separation plant KDON-20000/20000 solution for metallurgical industry
DEAR air separation has cooperated with customers in metallurgical industry domestic and abroad in many projects, and has rich project experience. DEAR has continuously invested in the research and development of large-scale air separation plant. In view of metallurgical industry, DEAR combined with the characteristic of this industry, develops high-efficiency energy-saving air separation plant, to meet the needs of large and medium customers. DEAR air separation uses the rapid development of internet technology to establish a remote monitoring system to collect real-time operation data of each air separation plant, and provides the best suggestions for users by using big data analysis.
Large air separation plant KDON-15000/35000 solution for metallurgical industry
DEAR air separation has cooperated with customers in metallurgical industry domestic and abroad in many projects, and has rich project experience. DEAR has continuously invested in the research and development of large-scale air separation plant. In view of different fields, DEAR combined with the characteristics of these industry, develops high-efficiency energy-saving air separation plant. DEAR air separation uses the rapid development of internet technology to establish a remote monitoring system to collect real-time operation data of each air separation plant, and provides the best suggestions for users by using big data analysis. The KDON-15000 / 35000 large scale air separation plant, cooperated with customers, has achieved rapid, stable and efficient operation, and highly affirmed by customer.
Faq of Air separation equipment customization
More
Air compressor intermediate cooler is generally shell-tube structure. Water is supplied inside the pipe, and gas is supplied between the pipes, which plays a cooling role through the heat exchange of fluid inside and outside the pipe. The reasons that affect the cooling effect of compressor intermediate cooler include: 1) insufficient cooling water. The heat of the air is not enough to be taken away by the cooling water, resulting in the increase of the next level of suction temperature, the decrease of gas density, and finally the reduction of exhaust volume. Therefore, the water supply pressure of cooling water should be closely monitored during operation to control the water supply. The process generally requires that the cooling water pressure should be greater than 0.15MPa (surface pressure); 2) the cooling water temperature is too high. High water temperature reduces the temperature difference between water and gas, and reduces the effect of heat and cooling. Even if the amoun...
Jan 09, 2025
1. The requirements of molecular sieve adsorber, electric heater and other equipment in place are the same as those of air cooling column of pre cooling system. 2. Process piping shall be constructed in strict accordance with relevant specifications and design and construction drawings. 3. The air tightness test shall be conducted before the valve is installed, and the test pressure and inspection standard shall be carried out according to the technical requirements of corresponding valves. 4. Pay attention to the direction of switch valve installation. V1201, V1202, V1207 and V1208 are front mounted valves, while V1203, V1204, V1205 and V1206 are reverse mounted valves. When the switch valve is installed, its shaft should be in a horizontal position, and the flange bolts should be evenly cross tightened. 5. The pipeline of pressure equalizing valve V1209 should have compensating bend.
Dec 11, 2024
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top