Precautions for installation of pipelines in air separation tower

Precautions for installation of pipelines in air separation tower
Nov 14, 2022
Author: DEAR AST

The pipelines in the air separation tower work at low temperature, but their installation is carried out at normal temperature. Therefore, if the prestress is too large or the cold compensation is not good, it is easy to cause pipe cracking, valve jamming and other phenomena. In order to avoid this problem, the following points should be done during installation: when piping, generally, large pipes should be done first and then small ones, difficult pipes should be done first and then easy ones, small pipes should give way to large ones, and heat pipes should give way to cold pipes; Do not force the installation when the dislocation of the welding junction between the valve and the pipe is too large; For the installation welded junction at the flange connecting the valve and vessel, tighten the flange bolt without gasket before welding, and add gasket after welding; Avoid using small tubes and valve stems as scaffolds; Change the valve hanger into a rigid support.

The remote monitoring system for hazardous chemical production equipment independently developed by Kaifeng DEAR Air Separation Industry Co., Ltd. has been verified to be widely used in the production of intelligent air separation system based on Internet remote control and the manufacturing equipment for energy saving and environmental protection industrial gas. The research results include DCS system, data acquisition system, customer remote monitoring system and manufacturer remote monitoring system. Multiple customer monitoring terminals work at the same time, which is conducive to effective management and normal operation of users, and can find and handle problems in a timely manner. The monitoring terminals of multiple manufacturers can help manufacturers obtain real-time information and historical data of equipment operation, and provide users with timely and accurate technical support.

DEAR Air Separation Solve YourPrecautions for installation of pipelines in air separation towerYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top