What emergency measures should be taken for partial failure of air separation unit

What emergency measures should be taken for partial failure of air separation unit
Aug 12, 2022
Author: DEAR AST

Some faults that may occur during the operation of the air separation unit and other unexpected faults shall be handled by the on-site operators according to the specific conditions.

The air supply stops and the alarm device of the air turbine compressor sounds. Consequence: the pressure in front of the booster compressor drops sharply, the system pressure and the resistance of the rectification tower drop, and the product purity is destroyed. If the product gas compressor (including cryogenic liquid pump) continues to operate, it will cause negative pressure on the rectification tower and relevant pipelines. Emergency measures: stop the operation of medium pressure liquid oxygen pump, medium pressure liquid argon pump, process liquid argon pump, booster compressor, booster turbine expander, product gas compressor, etc; Put the fractionator in a closed state; Stop regeneration of Molecular Sieve Purifier.

When the power supply is interrupted, all electrically driven machines stop working and the alarm device on these machines sounds. Consequence: the system pressure and the resistance of the rectification column decrease, and the product purity is destroyed.

Emergency measures: stop the operation of medium pressure liquid oxygen pump, medium pressure liquid argon pump, process liquid argon pump, booster turbine expander and relevant machines, and close the inlet and outlet valves. Place the fractionator in a closed state. Stop regeneration of Molecular Sieve Purifier. Disconnect a machine driven by electricity from the power grid. Stop the unit.

In the long-term business process of DEAR air separation, in addition to providing high-quality complete sets of air separation equipment for domestic and foreign customers, deer also provides customers with air separation equipment maintenance, energy saving and intelligent upgrading and transformation for a long time.

DEAR Air Separation Solve YourWhat emergency measures should be taken for partial failure of air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top