What emergency measures should be taken for partial failure of air separation unit

What emergency measures should be taken for partial failure of air separation unit
Aug 12, 2022
Author: DEAR AST

Some faults that may occur during the operation of the air separation unit and other unexpected faults shall be handled by the on-site operators according to the specific conditions.

The air supply stops and the alarm device of the air turbine compressor sounds. Consequence: the pressure in front of the booster compressor drops sharply, the system pressure and the resistance of the rectification tower drop, and the product purity is destroyed. If the product gas compressor (including cryogenic liquid pump) continues to operate, it will cause negative pressure on the rectification tower and relevant pipelines. Emergency measures: stop the operation of medium pressure liquid oxygen pump, medium pressure liquid argon pump, process liquid argon pump, booster compressor, booster turbine expander, product gas compressor, etc; Put the fractionator in a closed state; Stop regeneration of Molecular Sieve Purifier.

When the power supply is interrupted, all electrically driven machines stop working and the alarm device on these machines sounds. Consequence: the system pressure and the resistance of the rectification column decrease, and the product purity is destroyed.

Emergency measures: stop the operation of medium pressure liquid oxygen pump, medium pressure liquid argon pump, process liquid argon pump, booster turbine expander and relevant machines, and close the inlet and outlet valves. Place the fractionator in a closed state. Stop regeneration of Molecular Sieve Purifier. Disconnect a machine driven by electricity from the power grid. Stop the unit.

In the long-term business process of DEAR air separation, in addition to providing high-quality complete sets of air separation equipment for domestic and foreign customers, deer also provides customers with air separation equipment maintenance, energy saving and intelligent upgrading and transformation for a long time.

DEAR Air Separation Solve YourWhat emergency measures should be taken for partial failure of air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The main heat exchanger is the key equipment to ensure the performance of the air separation plant. Its functions in the air separation plant of the molecular sieve pre-filtration process are as follows: recover the cooling capacity of the reflux gas, ensure that the heat exchange temperature difference is within the design range; provide sufficient expansion gas in front of the expander to make up for the cooling loss of the air separation plant; provide raw air for the lower tower under the design conditions; and the working medium is in the main heat exchanger The resistance value in meets the process requirements.
2025.12.31
A low pressure nitrogen expander is added to the process design. The pressure nitrogen from the pressure tower and high pressure expander is expanded into low pressure nitrogen, which is combined with the nitrogen coming from the low pressure tower and fed into the charge gas compressor. This is specially set up for rapid oxygen load changes. The oxygen product flow rate during normal operation corresponds to the amount of oxygen contained in the amount of air entering the air separation unit. T...
2025.12.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top