Question Reply

The actual running current of 132kw-8 electric motor is 220A ~ 240A, 4-tableAir compressorShare An air storage tank, and the actual pressure required is 0.6 ~ 0.7Mpa, remote pressure gauge indication is 0.64Mpa. How to reform?

One, four setsAir compressorChange only one (132kw-8) Auxiliary with a pressure transmitter, and feed back the actual pressure of the sampling pipe network to the inverter. Inverter automatically adjusts output voltage through software (PID function. (That is to reduce the actual power) to meet the actual gas consumption. After agreement, in order not to affect the motor temperature, we adopt RB600-3P160G type (160kw inverter ).

II. Adopt manual switching of power/frequency conversion. If there is something wrong with the frequency converter, it can be changed to power frequency operation. It really does not affect the actual production of the factory, ensureAir compressorLong-term operation.

Third, according to the requirements of customers' pressure, the network management pressure can be set to 0.6Mpa, because there are fourAir compressorAt the same time, we will save the electric energy wasted by the three unmodified ones through the one converted by frequency conversion.

IV. According to the practical experience, the rebuilt inlet current is about 190A, and the saving power is about 30/2 = 15kw. Power = kilowatt/hour (namely 15 degrees/hour), running in 24 hours, saving power per day = 15*24 = 360 degrees. Calculate by 0.5 yuan per degree = 360*0.5 = 180 yuan/day. Monthly = 180*30 = 5400 yuan.

V. Benefits after frequency conversion transformation of air compressor:

1. Save Energy; 2. Reduce the operating cost; 3. Increase the precision of pressure; 4. Extend the service life of compressor; 5. LowerAir compressorNoise

DEAR Air Separation Solve YourMethod of reforming air compressorYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Water evaporation, wind-blown losses and other situations occurring in industrial circulating cooling water system operation, resulting in the continuous concentration of circulating water, then the salts contained therein exceed the standard, anions and cations increase, PH value changes significantly, resulting in the deterioration of water quality. The temperature of the circulating water rises and the PH value and nutrients increase, which is conducive to the reproduction of microorganisms. ...
2026.06.03
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top