The design speed of the turboexpander is 20000r/min, and the maximum speed is 23000r/min. The rotor of the turboexpander is generally composed of a main shaft, a working wheel and a booster wheel, which is a typical cantilever rotor structure.
Products of Small air separation unit expander speed
DEAR air separation has provided many sets of air separation plant for chemical industry for many years, with rich experience and the safe and stable unit operation. This unit adopts molecular sieve purification, booster turbine expander to supply the cooling capacity of the unit, and the whole rectification hydrogen-free argon production process. The rapid growth of enterprises in the industry is accompanied by the demand for production and the demand for air separation plant. DEAR air separation has cooperated with customers in the large-scale complete set of air separation plant KDON (AR) - 36000/70000-1200 project, which provides customers air separation plant with mature technology, reliable and convenient operation, and energy saving intelligence, which improves the production efficiency of customers, saving the operation cost and creates greater economic benefits.
DEAR air separation has provided many sets of air separation plant for chemical industry for many years, with rich experience and the safe and stable unit operation. This unit adopts molecular sieve purification, booster turbine expander to supply the cooling capacity of the unit, and the whole rectification hydrogen-free argon production process. The rapid growth of enterprises in the industry is accompanied by the demand for production and the demand for air separation plant. DEAR air separation has cooperated with customers in the large-scale complete set of air separation plant KDON (AR) - 36000/70000-1200 project, which has meet the capacity demand and safety demand of the enterprise.
When the main condenser evaporator leaks seriously, a large amount of high-pressure nitrogen will leak to the low-pressure oxygen side, and the pressure of the upper and lower columns and the purity of the product will change significantly until normal production cannot be maintained.
When the main condenser evaporator leaks slightly, the pressure of the upper and lower columns will not change significantly, and the purity of liquid oxygen in the main condenser evaporator will not decrease significantly. The common phenomenon is that the purity of the gas and liquid oxygen in the main condensing evaporator is very different, and the gas concentration is lower than that in equilibrium with liquid oxygen. For example, the concentration of liquid oxygen is 99% and that of gaseous oxygen is 96%, that 7 main cooling pipes were found to be leaking during maintenance.
The common causes of leakage are as follows:
1. Pipes are worn due to mutual vibration. For long tube condensing evap