Sieve tray column, also known as foam tower, has the advantages of simple structure, low maintenance workload, high purification efficiency, high water consumption and good anticorrosion performance. It is commonly used in the absorption of gas pollutants, and also has good trap effect on particulate pollutants. It is suitable for purifying dust with weak hydrophilicity, such as silica, clay, etc., but it cannot be used for purifying hydraulic dust such as lime, dolomite, clinker, etc., so as not to block the sieve. The flow rate of the dust collector should be controlled within 2 ~ 3m / s. if the wind speed is too high, it is easy to bring water and affect the dust removal efficiency. The dust removal efficiency of the foam precipitator is 90% to 93%. After adding plastic balls or pebbles on the foam board, the purification efficiency can be further improved, but the resistance of the equipment increases.
Faq of Sieve tray tower
More
When the power supply of the air separation unit of the molecular sieve adsorption purification process is resumed after the power failure, the operation should be conducted according to the following steps: 1) the possible influence on the mechanical equipment such as the air compressor when the power is suddenly cut off should be judged. If there is no influence, start-up preparation of the air compressor according to the operation specification of the air compressor; 2) check and confirm the switch state of the chain shutdown equipment valve; 3) check and confirm the alarm chain project of the air separation plant. Re-check and confirm the chain control of failure during power failure; 4) start the air compressor and air precooling system according to regulations; 5) start the molecular sieve adsorber according to regulations. Continue to complete the process before shutdown. If the downtime is long (more than 24 hours), the molecular sieve adsorber should recycle for one cycle; ...
Oct 10, 2024
Users reported that the on-line analyzer of a 30000 grade air separation plant showed that the outlet CO₂of the molecular sieve suddenly increased from the normal value of 0.43×10-6 to 120×10-6, and the temperature difference in the expansion air channel entering the two high-pressure plate fin heat exchangers began to expand. At the same time, the temperature in front of expander also decreased from - 105°C to - 132°C with liquid entrainment. After receiving the user's notice, DEAR air separation sent technical personnel to the site for observation and detection. It was found that the location of the self-cleaning filter of the equipment was close to the chemical boundary area. When the wind direction was in the downwind direction of the chemical industry boundary area, the phenomenon that the concentration of CO₂ in the air at the inlet of the self-cleaning filter of the air compressor exceeded the standard. In view of this phenomenon, the following opinions are given: 1. Sh
Aug 09, 2024
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top