Clogging of large air separation unit crude argon towers

Clogging of large air separation unit crude argon towers
Crude argon condenser evaporation, that is, crude argon tower load, once too large, will lead to an increase in the amount of nitrogen entering the top of the crude argon tower, time will cause nitrogen plugging, if the evaporation is too small, will lead to a reduction in the amount of argon liquid, directly affecting the argon extraction rate.
News of Clogging of large air separation unit crude argon towers
More
Dec 10, 2025
DEAR Air Separation Holds 'Expand Revenue and Reduce Costs' Strategy Seminar: Driving Customer Value Leap with Lean Management
Aug 26, 2021
On 26 April, Dear Air Separation was awarded as 2021 Provincial ‘professionalism, refinement, distinctiveness, innovation’ small and medium-sized ente
Albums of Clogging of large air separation unit crude argon towers
More
Solutions of Clogging of large air separation unit crude argon towers
More
Small air separation plant KDON (Ar)-3500/2000-75 solution for oil industry
DEAR air separation has many years of air separation plant manufacturing experience and has provided many sets of air separation plant for different customers in the oil industry for many years. The KDON (Ar) - 3500 / 2000-75 small air separation plant project cooperated by DEAR air separation and customers has helped enterprises to build more high-performance and high-quality products, which has been praised by customers.
Small air separation plant KDON(Ar)-1500+40Y/1500/40Y solution for metallurgical industry
DEAR air separation has provided a number of complete solutions for the metallurgical industry for many years, accumulated rich experience, and helped the efficient development of the metallurgical industry. With many years of service experience in the metallurgical industry, DEAR air separation provides foreign customer with the small air separation plant KDON(Ar)-1500+40Y/1500/40Y, which is mature technological, operating reliable, operating convenient, and energy saving intelligent, that is highly recognized by foreign customers.
Faq of Clogging of large air separation unit crude argon towers
More
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
Aug 18, 2026
In the condensation evaporator the liquid oxygen is heated to evaporate and the gas nitrogen is cooled and condensed. Both the liquid oxygen and the gas nitrogen are in a saturated state. If the saturation temperature of nitrogen is lower than the saturation temperature of oxygen at the same pressure, the purpose of condensing gas and nitrogen with liquid oxygen cannot be achieved. For this reason the heat transfer temperature difference in the condensing evaporator must be established by the pr...
Jun 05, 2026
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top