Air coolers in air separation units are used to reduce the temperature of compressed air before entering the air drying purifier and air separation tower, to avoid large fluctuations in the temperature of the inlet tower and to extract most of the moisture in the compressed air. Nitrogen water coolers are usually used.
News of Air cooler
More
Dec 12, 2016
1) insufficient cooling water. The heat of the air is not enough to be taken away by the cooling water, resulting in the increase of the next level of
Sep 24, 2013
After the cooling device runs for a period of time, the filling pebbles will gradually be compacted and sink due to the impact of air flow back and fo
Video of Air cooler
More
Faq of Air cooler
More
According to a DEAR air separation user, during the operation of a set of air separation plant that has been in operation for 5 years, it is found that under the condition that the inlet guide vane does not change, the expansion air volume of the expander gradually decreases, and the rotation speed of the expander gradually decreases, the outlet pressure of the booster end of the expander rises from 0.76MPa to 0.8MPa, the inlet temperature rises from - 110 ° C to - 95 ° C, and the working condition of the chilled water pump is poor.
Jun 13, 2025
In the temperature of the forward air into the cooler (hot end temperature, related to the cooling effect of the last cooler of the air compressor or nitrogen water precooler) and the temperature of the return air into the cooler (cold end temperature, under the condition that the temperature of the heat exchanger such as the outlet supercooler and the liquid purifier is not changed, the temperature difference between the thermal end and the temperature difference between the cold end of the refrigerator (both refers to the difference between the temperature of the forward air and the reflow gas participating in the switching) is interdependent. If the hot end temperature difference, cold end temperature difference will is too small; the hot end temperature difference is too small, cold end temperature difference will is too large. This is decided by the cooling balance of the positive and return gas of the cooler. When the ratio of return flow to positive flow volume is larger than...
Apr 28, 2025