The crude argon tower is closely related to the main tower distillation working conditions, mutual constraints, only when the main tower working condi
Crude argon condenser evaporation, that is, crude argon tower load, once too large, will lead to an increase in the amount of nitrogen entering the to
Argon fraction in the nitrogen content is too high, will affect the coarse argon condenser heat transfer work, serious when there will be nitrogen plu
The stability of the working conditions of the crude argon tower is mainly influenced by the composition of the argon fraction, the evaporation of the
The argon enrichment zone moves up, the oxygen content in the argon fraction is too high, and the crude argon tower, in addition to the increased oxyg
The upper tower reflux ratio becomes smaller, the argon fraction rises, and the rise of the argon fraction will accordingly affect the reduction of th
When the main tower conditions fluctuate it will directly affect the fluctuation of the argon fraction, as the location of the upper tower argon fract
When the argon fraction is lowered, the amount of air entering the lower tower is increased by increasing the amount of medium pressure air, i.e. by o
The high quality of the argon extraction rate of the air separation argon system mainly comes from the argon fraction of the upper tower, so the stabi
In adjusting the argon system working conditions must be adjusted at the same time air separation main tower good crude argon tower working conditions
The main tower of the air separation equipment is a prerequisite for the normal working conditions of the argon tower, while the good or bad runoff co
Liquid air separation plant continues to be large-scaled, with the progress of technology, the design of the piping in the cold box will certainly be