The argon enrichment zone moves up, the oxygen content in the argon fraction is too high, and the crude argon tower, in addition to the increased oxygen load, has to reduce the amount of crude argon liquid going to the argon tower in order to ensure the full fraction qualification rate, so that the argon yield is reduced, which leads to a lower argon extraction rate.