Air separation unit without hydrogen to argon system

Air separation unit without hydrogen to argon system
After the start-up of the air separation unit, it is not suitable to commission the crude argon column too early when the main column condition has not been established. Because the nitrogen content of argon fraction is very high at this time, it often causes nitrogen blockage in crude argon column. However, in actual operation, the vent valve of crude argon column is often fully opened, which leads to the increase of cold loss and is not conducive to the accumulation of liquid in the main column. The premise of adjusting the working condition of the main column is to ensure the stability of the lower column working condition, especially in the air separation unit with expanded air entering the lower column process.
Faq of Air separation unit without hydrogen to argon system
More
1. Before connecting the pipe orifice of each container, clean white cloth shall be used to tie the orifice to prevent grease and dirt from entering. 2. When welding in the cold box and in the condensing evaporator, it is strictly forbidden for flame or arc to touch the surface of vessels and pipes. 3. The containers, valves, pipes and corresponding supports in the cold box, the surface of the cold box and the foundation surface shall not be stained with grease after installation, otherwise, degreasing treatment shall be carried out.
Mar 12, 2026
Air cooling column is a mixed heat exchange device. The function is to make the cooling water fully contact with the air and being mixed fully to increase the heat transfer area and enhance the heat transfer, usually using "packed column" or "sieve plate". The packed column is a round steel container with packing (ceramic ring, plastic ring, etc.). Cooling water is ejected from the top of the column and mixed with air flowing upward from the bottom for heat and mass exchange. Air transfers heat to the cooling water, lowering its temperature and raising its temperature. In order to prevent the generation of water droplets in the air, the raschig ring (or stainless steel wire mesh) packing separator (also known as trapping layer) and mechanical water separator (inertial separation) are usually installed on the upper part of the column. The cooling water ejected from the spray device flows downward to the packing layer through the distributor, and an overflow ring is provided to redist
Feb 25, 2026