Process calculation of air separation unit plays an important role in the design of air separation unit. Its advanced nature directly affects whether the user can provide the air separation unit that can meet the production demand and run efficiently. With the popularization and application of computer technology, the process calculation technology of air separation unit has been developed. Designers can solve various complicated mathematical models by computer.
Faq of Air separation unit flow calculation
More
In the fractionating column, the separation of oxygen and nitrogen is realized through the process of two-stage distillation in the upper and lower columns. The distillation process must have ascending air and downflow liquid, and the main function of the condensing evaporator is to exchange heat between the liquid oxygen returned from the bottom of the upper column and the nitrogen rising from the top of the lower column. Condensing evaporator is an indispensable heat exchange equipment in air separation distillation system. In a sense, condensing evaporator is the link between upper column and lower column. The condensing evaporator is also called "main cooling". In the condensing evaporator, the liquid oxygen returned from the upper column absorbs heat and evaporates the gas oxygen; the rising nitrogen in the lower column is condensed into liquid nitrogen due to heat release. A part of the gas oxygen is sent out of the column as the product, and the rest is sent to the upper colu
Nov 04, 2020
According to the dye composition of penetrant, it can be divided into fluorescent penetrant testing, dye penetrant testing and fluorescent dye penetrant testing, which are represented by I, II and Ш respectively. According to the penetrant removal method, it can be divided into water washing type penetrant testing, lipophilic post emulsifying penetrant testing, solvent removing penetrant testing and hydrophilic post emulsifying penetrant testing, which are represented by A, B, C and D respectively; according to the type of imaging agent, it is divided into dry type Powder imaging agent, water soluble imaging agent, water suspension imaging agent, solvent suspension imaging agent and self imaging were expressed as a, b, c, d, e, respectively. II Cd means solvent removal dye penetrant testing, and the imaging agent is solvent suspension type.
Oct 16, 2020
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top